EN
UA RU EN

Oxygen Concentrator Letres LT-8

Price: 36 900,00 ₴SKU: 100043
Availability: In stock
Add modules to configuration*
Total: 36 900,00 ₴
Quantity:

The Letres LT-8 is an oxygen concentrator with an 8 L/min flow rate, 93 ± 3% oxygen concentration, and an outlet pressure ≤ 70 kPa. For long-term oxygen therapy in hospital, during rehabilitation, and at home.

Oxygen flow 8 L/minOxygen flow rate
O₂ concentration 93 ± 3%Oxygen concentration
Low noise ≤36 dBNoise level
Oxygen purity monitoringBuilt-in monitoring
4 standard alarmsPower, overheating, oxygen purity, maintenance
2-year / 20,000 h warrantyWarranty / service life
  • Description
  • Specifications
  • Configuration
  • Letres LT-8 — 8 L/min Oxygen Concentrator with 93 ± 3% Oxygen Concentration

    The Letres LT-8 operates on the principle of pressure swing adsorption (PSA) on zeolite and delivers an oxygen flow of 8 L/min. Oxygen concentration is 93 ± 3%, outlet pressure is ≤ 70 kPa.

    The model's power rating is 610 W, power supply 220 V, 50 Hz. Flowmeter accuracy is ±10%. Noise level is ≤ 50 dB.

    The unit weighs 25 kg, dimensions 372 × 340 × 612 mm. The rated service life is 20,000 hours, with a 2-year warranty.

    Standard alarms: power failure, overheating, low oxygen purity, and a maintenance reminder. The purity alarm triggers when the reading drops below 82%.

    Why this model is chosen

    Oxygen purity monitoringThe alarm triggers if oxygen purity drops below 82%.
    Maintenance reminderThe device reminds you itself when maintenance is needed.
    Defined warm-up timeWarm-up takes 5 minutes; restart is not allowed sooner than 5 minutes after shutdown.
    20,000-hour service lifeThe unit's rated service life is 20,000 hours, with a 2-year warranty.
    Flowmeter accuracy ±10%Flowmeter accuracy is ±10%.
    Standard alarmsAlarms are provided for power failure, overheating, low oxygen purity, and maintenance.

    What the facility gets

    Oxygen flow of 8 L/min
    Oxygen concentration of 93 ± 3%
    Outlet pressure ≤ 70 kPa
    Standard oxygen purity monitoring with an alarm threshold below 82%
    A 2-year warranty and a rated service life of 20,000 hours

    Operation and maintenance

    Wash the humidifier every 3 days, clean the filter cotton every 100 hours, and replace the HEPA filter every 1500 hours. The device reminds you about maintenance.

    Important

    Intended use: supplemental oxygen delivery. The device is not intended for life support and is not intended for first aid. Contraindication: severe carbon monoxide poisoning. Use is prohibited in an environment of flammable anesthetics mixed with air or nitrous oxide.

    When five liters is no longer enough

    Eight liters per minute is used when a patient needs more than the basic flow and running centralized oxygen to the ward is not feasible. It has the same housing as the junior models, but a more powerful 610 W compressor. The unit weighs 25 kg and sits on casters — it is moved between wards rather than permanently installed. If your department has patients with higher oxygen needs, it makes sense to buy the Letres LT-8 oxygen concentrator in Ukraine as an intermediate step between five-liter units and a stationary station. We can advise on how many units you actually need.

    * Options are factory-installed for a specific order and cannot be added to a unit already delivered. Check availability and lead time with your manager.

    • Operating principle:pressure swing adsorption on zeolite (PSA)
    • Oxygen flow:8 L/min
    • Oxygen concentration:93 ± 3%
    • Outlet pressure:≤ 70 kPa
    • Power:610 W
    • Power supply:220 V, 50 Hz
    • Noise level:≤ 50 dB
    • Weight:25 kg
    • Dimensions:372 × 340 × 612 mm
    • Warranty:2 years
    • Service life:20,000 hours
    • Standard alarms:power failure, overheating, low oxygen purity, maintenance reminder
    • Purity alarm threshold:below 82%
    • Flowmeter accuracy:±10%
    • Warm-up / restart:warm-up — 5 minutes; restart no sooner than 5 minutes after shutdown
    • Maintenance:wash humidifier every 3 days; filter cotton every 100 hours; replace HEPA filter every 1500 hours; the device reminds about maintenance
    • Intended use:Oxygen therapy in hospital and at home
    • Contraindications:severe carbon monoxide poisoning
    • Prohibition:use in an environment of flammable anesthetics mixed with air or nitrous oxide
    Oxygen concentrator1 pc
    Power cable1 pc
    Inlet filter cotton1 pc
    HEPA filter1 pc
    Humidifier with 3 PSI safety valve1 pc
    Nasal cannulas, 2 m, π-shaped2 pcs
    Oxygen connecting tube1 pc
    Instructions for use1 pc

    Compare models: Oxygen Concentrators

    Choose the model that fits your department.

    LT-5Oxygen flow up to 5 L/min · Concentration 93 ± 3% · Noise level ≤ 36 dBLT-10Oxygen flow up to 10 L/min · Concentration 93 ± 3% · Higher capacityLT-10-DFDual flow · 2 independent oxygen outlets · Up to 10 L/min combinedLT-20Oxygen flow up to 20 L/min · Concentration 93 ± 3% · Pressure 140–400 kPa
    INDIVIDUAL SELECTION

    We will find a solution for your facility

    We will help define the required specifications, choose the right equipment and agree on the best terms of cooperation.

    Related products

    Call Telegram Get a quote
    Telegram Viber