AXfusion VP-3 is a single-channel volumetric infusion pump for precise, continuous and controlled administration of medications, nutrients and other parenteral fluids. It supports five infusion modes, a flow rate of 0.1–1500 mL/h, multi-level occlusion control and air-in-line detection.

5 infusion modesRate, time, dose, sequential and drug library
Flow rate 0.1–1500 mL/hDrip mode 1–400 drops/min
Accuracy ±4.5 %Over 12 hours for infusion up to 1 L per EN/IEC 60601-2-24
14 occlusion levels30–160 kPa with automatic anti-bolus
7 IV set brandsBuilt-in parameters; calibration for other sets
Ukrainian-language interface UA menuPump menu in Ukrainian
Air-in-line controlAir sensor
BOLUS + KVOBolus administration and keep-vein-open function
  • Description
  • Specifications
  • Configuration
  • AXfusion VP-3 — a volumetric infusion pump with five operating modes

    VP-3 is designed for continuous administration of medications, nutrients and other parenteral fluids via clinically accepted intravenous routes. The pump allows setting infusion by rate, time or dose, performing sequential administration and working with a drug library.

    The device is not intended for transfusion of blood and its components, enteral feeding or home use.

    VP-3 features

    Five infusion modes: rate, time, dose, sequential and drug-library modes allow configuring the pump for different clinical scenarios. In sequential mode, up to three "volume — rate" stages can be set.

    Wide rate range: the infusion rate is adjustable from 0.1 to 1500 mL/h, with a step of 0.01 mL/h available at low values. A separate drip mode of 1–400 drops/min is also provided.

    Controlled administration accuracy: the stated accuracy is ±4.5% over 12 hours for infusion up to 1 L, per EN/IEC 60601-2-24.

    14 occlusion control levels: the pressure alarm threshold is adjustable from 30 to 160 kPa. When the alarm triggers, the system automatically releases accumulated pressure using an anti-bolus mechanism, and the maximum line pressure is limited to 200 kPa.

    Air-in-line control: the sensor detects single air bubbles from 15 μL and separately monitors accumulated air volume over 15 minutes.

    BOLUS, flushing and KVO: bolus administration, flushing and keep-vein-open modes are provided; KVO is adjustable in the range of 0.1–20 mL/h.

    Compatibility with infusion sets: the pump's memory holds parameters for 7 brands of IV sets, with calibration available for other consumables.

    Autonomous operation of about 5 hours: a 7.2 V / 2600 mAh lithium-polymer battery provides about 5 hours of operation at a rate of 25 mL/h, so infusion continues during patient transport or a temporary mains power loss.

    What the facility gets

    One pump for different infusion therapy modes
    Wide rate range of 0.1–1500 mL/h
    Accuracy of ±4.5% per EN/IEC 60601-2-24
    14 occlusion control levels with anti-bolus
    Control of single and accumulated air bubbles
    BOLUS, flushing and KVO
    Support for several types of IV sets with calibration option
    Autonomous operation of about 5 hours
    Ukrainian-language interface
    IPX4 rating and a defibrillation-proof type CF applied part

    Precise infusion control in one compact pump

    VP-3 combines five infusion modes, a wide rate range, occlusion and air-in-line control, autonomous power and a Ukrainian-language interface. It is a versatile volumetric pump for departments where precise dosing, safety control and flexible infusion therapy setup matter.

    Letres Company will help select equipment for your department's needs — leave a request, and we will prepare a commercial offer with the current price, configuration and delivery terms.

    Compare infusion equipment models

    Choose a pump by infusion type, number of channels and administration modes.

    Volumetric pump

    VP-3 Current model0.1–1500 mL/h — 5 modes, occlusion and air-in-line control

    Syringe pumps

    • Type:volumetric infusion pump, single-channel
    • Interface:Ukrainian-language
    • Modes:rate, time, dose, sequential, drug library
    • Rate:0.1–1500 mL/h
    • Drip mode:1–400 drops/min
    • Accuracy:±4.5 %
    • Infusion volume:0.0–9999.9 mL
    • Infusion time:00:00:01–99:59:59
    • BOLUS:0.1–1500 mL/h
    • KVO:0.1–20 mL/h
    • Occlusion:14 levels, 30–160 kPa
    • Maximum pressure:200 kPa
    • Air control:single bubble 15–1000 μL
    • Compatible IV sets:7 programmed brands, calibration for others
    • Battery:Li-ion polymer 7.2 V / 2600 mAh
    • Autonomous operation:about 5 h at 25 mL/h
    • Power supply:220 V, 50 Hz
    • Protection:IPX4
    • Classification:class I, type CF applied part, defibrillation-proof
    • Dimensions:120 × 100 × 215 mm
    • Weight:1.5 kg
    Infusion pump 1 pc.
    Power cord 1 pc.
    Instructions with warranty card 1 pc.
    Quality certificate 1 pc.
    Packing list 1 pc.
    INDIVIDUAL SELECTION

    We will find a solution for your facility

    We will help define the required specifications, choose the right equipment and agree on the best terms of cooperation.

    Related products

    Call Telegram Get a quote
    Telegram Viber