AXfusion SP-1 is a single-channel syringe pump for precise, metered administration of medications. It supports three main infusion modes — by rate, time, and dose, works with 5–60 mL syringes, and can be combined with other pumps into a multi-channel system.

3 administration modesRate, time, and dose
5–60 mL syringes13 pre-loaded brands, calibration for others
Flow rate up to 2000 mL/hFor a 50/60 mL syringe; step 1 / 0.1 / 0.01 mL/h
Accuracy ±2%After calibration; mechanical accuracy ±1%
25 occlusion levels20–160 kPa with automatic anti-bolus
Ukrainian-language interface UA menuPump menu in Ukrainian
  • Description
  • Specifications
  • Configuration
  • AXfusion SP-1 — Single-Channel Syringe Pump for Metered Administration

    The AXfusion SP-1 is a single-channel syringe pump for precise, controlled administration of medications in intensive care units, anesthesiology departments, operating rooms, and inpatient wards. The model supports three main infusion modes — by rate, time, and dose, works with 5–60 mL syringes, and allows precise adjustment of administration according to the prescribed therapy.

    The SP-1 is suitable for situations that require predictable single-channel operation without complex multi-step programs.

    SP-1 features

    Three main infusion modes: rate, time, and dose modes allow the pump to be used for most standard syringe administration protocols — staff set parameters according to the prescribed volume, duration, or calculated dose.

    Works with 5–60 mL syringes: support for 5, 10, 20, 30, and 50/60 mL sizes allows the pump to be used for different volumes and infusion rates.

    Rate up to 2000 mL/h: the rate range depends on the syringe installed and allows work with both slow, long-term infusions and more intensive administration.

    Administration accuracy ≤ ±2% after calibration: calibration for a specific syringe type maintains the set dosing accuracy and reduces the effect of differences between consumables from different manufacturers.

    25 occlusion control levels: the pressure threshold is adjustable in the range of 20–160 kPa, which allows the system’s sensitivity to be adapted to the infusion rate, syringe type, and clinical scenario.

    BOLUS and KVO: the pump supports bolus administration and a keep-vein-open mode after the main infusion is completed.

    Support for different syringe brands: the memory includes parameters for 13 syringe manufacturers, and other consumables can be calibrated before use.

    Workstation scalability: the SP-1 can be used standalone or combined with other pumps into a multi-channel workstation of up to 8 pumps — convenient for simultaneous administration of several medications to one patient.

    What the facility gets

    One channel for controlled syringe administration
    Three clear infusion modes
    Works with 5–60 mL syringes
    Accuracy ≤ ±2% after calibration
    Rate up to 2000 mL/h depending on syringe size
    25 occlusion control levels
    BOLUS and KVO
    Ability to calibrate consumables
    Ability to build a multi-channel workstation of up to 8 pumps
    A compact solution for everyday infusion therapy

    Precise control of standard syringe infusion

    The SP-1 is designed for departments that need a reliable single-channel pump with three main administration modes and broad syringe compatibility. The model can be used standalone or scaled up to an eight-pump workstation as the number of simultaneous infusions grows.

    Letres Company will help select an infusion equipment configuration for your department’s needs — leave a request, and we will prepare a commercial offer with the current price, kit, and delivery terms.

    Compare infusion equipment models

    Choose a pump by infusion type, number of channels, and administration modes.

    Volumetric pump

    Syringe pumps

    • Type:syringe infusion pump, single-channel, stackable (up to 8 channels in a stack)
    • Interface:Ukrainian-language
    • Administration modes:rate, time, dose
    • Compatible syringes:5, 10, 20, 30, 50/60 mL; 13 pre-loaded brands, calibration for others
    • Administration rate:5 mL: 0.1–200.0 mL/h; 10 mL: 0.1–400.0; 20 mL: 0.1–800.0; 30 mL: 0.1–1200.0; 50/60 mL: 0.1–2000.0 mL/h; step 1 / 0.1 / 0.01 mL/h
    • Accuracy:± 2% after calibration; mechanical accuracy ± 1%
    • Infusion volume and time:volume 0.0–9999.9 mL (step 0.1 mL); time 00:00:01–99:59:59 (step 1 s)
    • BOLUS and KVO:BOLUS 1.0–50.0 mL (step 0.1 mL), rate up to 2000.0 mL/h; KVO 0.1–20 mL/h or the last administration rate
    • Occlusion alarm:25 levels, 20–160 kPa (±15 kPa); automatic anti-bolus, release ≤ 0.5 mL; maximum pressure 250 kPa
    • Dose mode parameters:dose 0.001–9999; patient weight 0.1–300.0 kg; drug mass 0.1–999.9 mg; solution volume 0.1–999.9 mL
    • Wi-Fi:optional; 2.4 GHz module
    • Power supply:220 V, 50 Hz with protective grounding; maximum power 35 VA; consumption < 10 W; optional external DC 12–15 V
    • Battery:lithium-polymer 7.2 V / 2600 mAh; ~8 h at a rate of 5 mL/h; charging < 10 h (off), < 14 h (operating)
    • Classification:Class I with internal power source; type CF applied part; continuous operating mode; IPX4
    • Dimensions and weight:265 × 160 × 117 mm (excluding clamp protrusion); 2.1 kg
    • Operating conditions:5…40 °C; humidity 15–95% non-condensing; pressure 70–106 kPa, altitude ≤ 3000 m
    Syringe pump 1 pc
    Power cord 1 pc
    Operating instructions (with warranty card) 1 pc
    Quality certificate 1 pc
    Packing list 1 pc
    INDIVIDUAL SELECTION

    We will find a solution for your facility

    We will help define the required specifications, choose the right equipment and agree on the best terms of cooperation.

    Related products

    Call Telegram Get a quote
    Telegram Viber