EN
UA RU EN

Patient Monitor with Capnography Letres iHT6 (Sidestream)

Price: 201 800,00 ₴SKU: 100056
Availability: In stock
Add modules to configuration*
Total: 201 800,00 ₴
Quantity:

The expert-class patient monitor Letres iHT6 configured with sidestream capnography for continuous EtCO₂ monitoring. The gas sample is drawn through a thin sampling line, so capnography can be used in both intubated and non-intubated patients.

iHT6 expert platform
Sidestream capnography
Intubated and non-intubated
Continuous EtCO₂ monitoring
CO₂ waveform and AwRR
Sampling through a thin line
Further modular expansion
Ukrainian-language interface UA menuMonitor menu available in Ukrainian
  • Description
  • Specifications
  • Configuration
  • Letres iHT6 Patient Monitor with Sidestream Capnography

    Letres iHT6 in the Sidestream configuration complements standard patient monitoring with continuous airway carbon dioxide monitoring. The system displays the capnogram, EtCO₂, inspired CO₂ concentration and the respiratory rate calculated from the CO₂ waveform.

    The key feature of sidestream is how the sample is obtained. The gas is not analysed directly in an adapter at the patient: a small amount is continuously drawn from the airway through a thin line and delivered to the module’s CO₂ sensor.

    This design makes Sidestream a flexible configuration. It can be used not only in patients with a closed breathing circuit but also in non-intubated patients with suitable consumables.

    Capnography for different monitoring scenarios

    Sidestream makes sense where one monitor has to be used in different clinical situations.

    During mechanical ventilation the sample can be taken directly from the breathing circuit. During sedation or monitoring of a spontaneously breathing patient, suitable nasal or other sampling systems can be used.

    So the main advantage of this configuration is not just having EtCO₂, but the versatility of how it is obtained.

    What capnography displays

    The system provides:

    real-time CO₂ waveform
    EtCO₂ — CO₂ concentration at the end of expiration
    INS/FiCO₂ — the lowest CO₂ concentration during inspiration
    AwRR — respiratory rate calculated from the capnogram

    These parameters are shown alongside the other iHT6 values, so the physician can assess ventilation, oxygenation and haemodynamic status at the same time.

    Letres iHT6 Sidestream — Key Features

    Versatile sampling — capnography can be used with different types of breathing systems and clinical scenarios.
    For intubated and non-intubated patients — Sidestream is not limited to patients with an endotracheal tube on a ventilator.
    Continuous EtCO₂ — the monitor tracks the CO₂ concentration at the end of each expiration.
    Real-time capnogram — the shape of the CO₂ waveform gives additional information about ventilation and the breathing circuit.
    Inspired CO₂ monitoring — INS/FiCO₂ shows the residual carbon dioxide concentration during inspiration.
    AwRR calculation — respiratory rate is determined directly from the CO₂ waveform.
    Integration into the iHT6 — capnography works together with the patient’s other parameters on one monitor.
    Modular expansion — the configuration can be extended with IBP, C.O., CSM and other available modules.

    What Your Facility Gets

    One capnography configuration for different patient groups — Sidestream suits monitors used with both intubated and non-intubated patients.
    Real-time ventilation monitoring — EtCO₂, the CO₂ waveform and AwRR add direct ventilation information to standard monitoring.
    Flexible use — one measuring principle can be used in intensive care, anaesthesia, sedation and other scenarios.
    A single workstation — CO₂ and other vital parameters are shown on one iHT6.
    Room for further expansion — the facility can add new modules without replacing the main platform.
    Ukrainian-language interface Menu — the Ukrainian interface makes everyday work easier for staff.

    Who It Is For

    The Sidestream configuration suits departments where maximum capnography versatility matters: intensive care, anaesthesia, post-operative observation and monitoring during sedation.

    Letres iHT6 Sidestream for Your Facility

    Letres iHT6 Sidestream is a flexible capnography configuration of the series for EtCO₂ monitoring in both intubated and non-intubated patients.

    Letres Company will help select the sampling lines, accessories and additional modules for your department’s tasks.

    • SpO₂ / pulse:SpO₂ 0–100%, accuracy ±2% (70–100%); PR 0–254 bpm, ±2; perfusion index (PI)
    • Capnography module:sidestream, infrared method; CO₂ 0–150 mmHg (0–19.7%); accuracy ±2 mmHg (CO₂ < 5%), < 6% of reading (CO₂ > 5%); AwRR 7–120 bpm (adults), 7–150 (children, neonates); delay < 3 s; sample flow 50 ± 10 mL/min
    • Display:12.1″ color TFT LCD
    • Interface:Ukrainian-language
    • Patient categories:adults, children, neonates
    • ECG:3-lead (I, II, III), 5-lead (+aVR, aVL, aVF, V) or 12-lead (option: I, II, III, aVR, aVL, aVF, V1–V6); HR 15–300 bpm, accuracy ±1%; ST analysis, arrhythmia detection
    • Respiration (RESP):impedance method; 0–120 br/min (adults), 0–150 (children/neonates); apnea alarm
    • NIBP:oscillometric; manual / auto / STAT; SYS 40–270, DIA 10–215, MEAN 20–235 mmHg; accuracy ±5 mmHg
    • Temperature:2 channels (T1/T2); 0–50 °C, ±0.1 °C
    • Defibrillation protection:yes, signal recovery < 3 s
    • Power supply:100–240 V, 50/60 Hz; built-in battery
    • Operating conditions:0…+40 °C, humidity ≤ 85%
    Main monitor unit 1 pc
    ECG cable (5-lead) 1 pc
    NIBP cuff and extension tube 1 set
    SpO₂ sensor 1 pc
    Temperature sensor 1 pc
    Power and grounding cable 1 set
    Disposable ECG electrodes 5 pcs
    Configurations iHT6
    Choose a module for your clinical task
    Base EtCO₂ sidestream EtCO₂ mainstream Masimo CO₂ AG gases BIS anesthesia C.O. output
    What it measures 6 parametersCO₂ gas samplingCO₂ in circuitCO₂ Masimo5 gases + MACEEG brain activitycardiac output
    For whom intensive careall patientsintubatedICUanesthesiaanesthesiahemodynamics
    Price 156 900201 800201 800291 800605 800605 800274 800
    INDIVIDUAL SELECTION

    We will find a solution for your facility

    We will help define the required specifications, choose the right equipment and agree on the best terms of cooperation.

    Related products

    Call Telegram Get a quote
    Telegram Viber