We will find a solution for your facility
We will help define the required specifications, choose the right equipment and agree on the best terms of cooperation.
The expert-class patient monitor Letres iHT6 configured with sidestream capnography for continuous EtCO₂ monitoring. The gas sample is drawn through a thin sampling line, so capnography can be used in both intubated and non-intubated patients.
Letres iHT6 in the Sidestream configuration complements standard patient monitoring with continuous airway carbon dioxide monitoring. The system displays the capnogram, EtCO₂, inspired CO₂ concentration and the respiratory rate calculated from the CO₂ waveform.
The key feature of sidestream is how the sample is obtained. The gas is not analysed directly in an adapter at the patient: a small amount is continuously drawn from the airway through a thin line and delivered to the module’s CO₂ sensor.
This design makes Sidestream a flexible configuration. It can be used not only in patients with a closed breathing circuit but also in non-intubated patients with suitable consumables.
Capnography for different monitoring scenarios
Sidestream makes sense where one monitor has to be used in different clinical situations.
During mechanical ventilation the sample can be taken directly from the breathing circuit. During sedation or monitoring of a spontaneously breathing patient, suitable nasal or other sampling systems can be used.
So the main advantage of this configuration is not just having EtCO₂, but the versatility of how it is obtained.
What capnography displays
The system provides:
These parameters are shown alongside the other iHT6 values, so the physician can assess ventilation, oxygenation and haemodynamic status at the same time.
Letres iHT6 Sidestream — Key Features
What Your Facility Gets
Who It Is For
The Sidestream configuration suits departments where maximum capnography versatility matters: intensive care, anaesthesia, post-operative observation and monitoring during sedation.
Letres iHT6 Sidestream for Your Facility
Letres iHT6 Sidestream is a flexible capnography configuration of the series for EtCO₂ monitoring in both intubated and non-intubated patients.
Letres Company will help select the sampling lines, accessories and additional modules for your department’s tasks.
| Main monitor unit | 1 pc |
| ECG cable (5-lead) | 1 pc |
| NIBP cuff and extension tube | 1 set |
| SpO₂ sensor | 1 pc |
| Temperature sensor | 1 pc |
| Power and grounding cable | 1 set |
| Disposable ECG electrodes | 5 pcs |
| Base | EtCO₂ sidestream | EtCO₂ mainstream | Masimo CO₂ | AG gases | BIS anesthesia | C.O. output | |
|---|---|---|---|---|---|---|---|
| What it measures | 6 parameters | CO₂ gas sampling | CO₂ in circuit | CO₂ Masimo | 5 gases + MAC | EEG brain activity | cardiac output |
| For whom | intensive care | all patients | intubated | ICU | anesthesia | anesthesia | hemodynamics |
| Price | 156 900 | 201 800 | 201 800 | 291 800 | 605 800 | 605 800 | 274 800 |
We will help define the required specifications, choose the right equipment and agree on the best terms of cooperation.