We will find a solution for your facility
We will help define the required specifications, choose the right equipment and agree on the best terms of cooperation.
The expert-class patient monitor Letres iHT6 with AG module is designed for advanced anaesthesia monitoring with control of respiratory and anaesthetic gas concentrations. It tracks CO₂, O₂, N₂O and the inhalational anaesthetics in use, evaluates MAC and combines gas monitoring with the patient’s other parameters on the single modular iHT6 platform.
Letres iHT6 configured with the AG module is designed for operating rooms, anaesthesia workstations and other clinical areas where it is necessary to monitor not only the patient’s standard physiological parameters but also the composition of the breathing mixture and anaesthetic gas concentrations.
The AG module tracks key gas values during anaesthesia, including CO₂, O₂, N₂O and inhalational anaesthetic concentrations. The data are shown directly on the monitor together with the patient’s other parameters, creating a single working environment for the anaesthesiologist.
The key advantage of this configuration is the ability to combine gas monitoring with the basic and additional iHT6 parameters. If needed, the system can be extended with IBP, C.O., BIS/CSM and other available modules without moving to a separate monitoring platform.
Monitoring of anaesthetic and respiratory gases
During inhalational anaesthesia it is important to monitor not only the patient’s condition but also the actual gas concentrations in the breathing circuit.
The AG module measures CO₂, O₂, N₂O and inhalational anaesthetic concentrations, giving the physician information about the composition of the gas mixture during anaesthesia.
Monitoring of expired and inspired CO₂ helps assess ventilation, while anaesthetic concentration monitoring tracks the actual level of the inhalational agent in the breathing mixture.
The MAC value complements gas monitoring with an index used to assess the inhalational anaesthetic concentration relative to standard anaesthetic potency.
Available parameters
Depending on the AG module configuration, the system can display:
These data can be assessed together with ECG, SpO₂, NIBP, RESP, TEMP, IBP, BIS/CSM and other parameters available in the iHT6 system.
What the physician sees
Gas parameters are shown on the monitor screen together with the patient’s other data, so the patient’s condition and anaesthesia parameters can be assessed in one working environment.
The physician gets numerical gas concentrations, waveforms and calculated values needed to monitor ventilation and inhalational anaesthesia.
This makes it possible to analyse changes in gas composition not in isolation, but in the context of the patient’s overall condition and other monitoring parameters.
Letres iHT6 with AG Module — Key Features
What Your Facility Gets
Who the Letres iHT6 with AG Module Is For
The AG configuration suits operating rooms, anaesthesia workstations and other clinical areas where inhalational anaesthetics are used and constant monitoring of the breathing mixture is required.
It is especially relevant where gas monitoring must work together with haemodynamic, respiratory and other patient parameters within one system.
The modular iHT6 platform allows both a specialised anaesthesia configuration and a comprehensive system with additional modules.
A Configuration for Your Operating Room
The Letres iHT6 is not limited to a fixed set of parameters. The AG configuration can be extended with other modules for the tasks of a specific facility.
IBP, C.O., BIS/CSM and other available modules can be added to the system.
Before ordering, the required parameters, sensors and accessories can be agreed so that the system fits the real use case in the operating room or anaesthesia department.
Letres iHT6 with AG Module for Your Facility
The Letres iHT6 with AG combines anaesthetic and respiratory gas monitoring with control of the patient’s vital parameters and further expansion on a single expert platform.
Letres Company will help select the right configuration, confirm the scope of delivery and prepare technical documentation and a commercial offer for equipping an operating room or anaesthesia workstation.
| Monitor main unit | 1 pc. |
| ECG cable (5-lead) | 1 pc. |
| NIBP cuff and extension tube | 1 set |
| SpO₂ sensor | 1 pc. |
| Temperature sensor | 1 pc. |
| Power and grounding cable | 1 set |
| Disposable ECG electrodes | 5 pcs. |
| Base | EtCO₂ sidestream | EtCO₂ mainstream | Masimo CO₂ | AG gases | BIS anesthesia | C.O. output | |
|---|---|---|---|---|---|---|---|
| What it measures | 6 parameters | CO₂ gas sampling | CO₂ in circuit | CO₂ Masimo | 5 gases + MAC | EEG brain activity | cardiac output |
| For whom | intensive care | all patients | intubated | ICU | anesthesia | anesthesia | hemodynamics |
| Price | 156 900 | 201 800 | 201 800 | 291 800 | 605 800 | 605 800 | 274 800 |
We will help define the required specifications, choose the right equipment and agree on the best terms of cooperation.