The expert-class patient monitor Letres iHT6 with AG module is designed for advanced anaesthesia monitoring with control of respiratory and anaesthetic gas concentrations. It tracks CO₂, O₂, N₂O and the inhalational anaesthetics in use, evaluates MAC and combines gas monitoring with the patient’s other parameters on the single modular iHT6 platform.

Expert platform iHT6
AG Masimo anesthetic gas analysis
CO₂ and N₂O
Sevoflurane • Desflurane • Isoflurane
Enflurane • Halothane
Automatic agent recognition
MAC and AwRR calculation
Ukrainian-language interface UA menuDevice menu in Ukrainian
  • Description
  • Specifications
  • Configuration
  • Letres iHT6 Patient Monitor with AG Module

    Letres iHT6 configured with the AG module is designed for operating rooms, anaesthesia workstations and other clinical areas where it is necessary to monitor not only the patient’s standard physiological parameters but also the composition of the breathing mixture and anaesthetic gas concentrations.

    The AG module tracks key gas values during anaesthesia, including CO₂, O₂, N₂O and inhalational anaesthetic concentrations. The data are shown directly on the monitor together with the patient’s other parameters, creating a single working environment for the anaesthesiologist.

    The key advantage of this configuration is the ability to combine gas monitoring with the basic and additional iHT6 parameters. If needed, the system can be extended with IBP, C.O., BIS/CSM and other available modules without moving to a separate monitoring platform.

    Monitoring of anaesthetic and respiratory gases

    During inhalational anaesthesia it is important to monitor not only the patient’s condition but also the actual gas concentrations in the breathing circuit.

    The AG module measures CO₂, O₂, N₂O and inhalational anaesthetic concentrations, giving the physician information about the composition of the gas mixture during anaesthesia.

    Monitoring of expired and inspired CO₂ helps assess ventilation, while anaesthetic concentration monitoring tracks the actual level of the inhalational agent in the breathing mixture.

    The MAC value complements gas monitoring with an index used to assess the inhalational anaesthetic concentration relative to standard anaesthetic potency.

    Available parameters

    Depending on the AG module configuration, the system can display:

    EtCO₂
    FiCO₂
    O₂ concentration
    N₂O concentration
    inhalational anaesthetic concentrations
    MAC value
    CO₂ respiratory waveform
    other related gas parameters available in a given configuration

    These data can be assessed together with ECG, SpO₂, NIBP, RESP, TEMP, IBP, BIS/CSM and other parameters available in the iHT6 system.

    What the physician sees

    Gas parameters are shown on the monitor screen together with the patient’s other data, so the patient’s condition and anaesthesia parameters can be assessed in one working environment.

    The physician gets numerical gas concentrations, waveforms and calculated values needed to monitor ventilation and inhalational anaesthesia.

    This makes it possible to analyse changes in gas composition not in isolation, but in the context of the patient’s overall condition and other monitoring parameters.

    Letres iHT6 with AG Module — Key Features

    Anaesthetic gas monitoring — The system monitors inhalational anaesthetic concentrations during anaesthesia.
    CO₂ monitoring — EtCO₂, FiCO₂ and capnogram display for assessing ventilation.
    O₂ and N₂O monitoring — Monitoring of oxygen and nitrous oxide concentrations in the breathing mixture.
    MAC calculation — The MAC value complements inhalational anaesthetic concentration monitoring.
    Unified parameter display — Gas and physiological values are available on a single monitor.
    Integration with other modules — AG can work together with IBP, C.O., BIS/CSM and other available iHT6 technologies.
    Modular configuration — The system can be built around the tasks of a specific operating room or anaesthesia workstation.
    Five anaesthetic agents — The module measures halothane, enflurane, isoflurane, sevoflurane and desflurane.

    What Your Facility Gets

    Full control of the gas environment during anaesthesia — The AG module tracks key respiratory and anaesthetic gases on a single monitor.
    A single anaesthesiologist workstation — Gas values, haemodynamics, oxygenation and other parameters can be shown in one system.
    Control of the actual anaesthetic concentration — The physician gets data not only on drug delivery but also on its concentration in the breathing mixture.
    Ventilation monitoring alongside anaesthesia — EtCO₂, FiCO₂ and the capnogram add ventilation information to gas monitoring.
    A system built for a specific operating room — The configuration can be extended with other modules for the department’s tasks.
    Further expansion without replacing the monitor — As requirements change, the facility can add new modules while keeping the base iHT6 platform.
    A unified environment for staff — One control logic and a single interface for different parameters make daily work easier.
    Ukrainian-language interface Menu — The system is adapted for everyday use by staff of Ukrainian medical facilities.

    Who the Letres iHT6 with AG Module Is For

    The AG configuration suits operating rooms, anaesthesia workstations and other clinical areas where inhalational anaesthetics are used and constant monitoring of the breathing mixture is required.

    It is especially relevant where gas monitoring must work together with haemodynamic, respiratory and other patient parameters within one system.

    The modular iHT6 platform allows both a specialised anaesthesia configuration and a comprehensive system with additional modules.

    A Configuration for Your Operating Room

    The Letres iHT6 is not limited to a fixed set of parameters. The AG configuration can be extended with other modules for the tasks of a specific facility.

    IBP, C.O., BIS/CSM and other available modules can be added to the system.

    Before ordering, the required parameters, sensors and accessories can be agreed so that the system fits the real use case in the operating room or anaesthesia department.

    Letres iHT6 with AG Module for Your Facility

    The Letres iHT6 with AG combines anaesthetic and respiratory gas monitoring with control of the patient’s vital parameters and further expansion on a single expert platform.

    Letres Company will help select the right configuration, confirm the scope of delivery and prepare technical documentation and a commercial offer for equipping an operating room or anaesthesia workstation.

    • SpO₂ / pulse:SpO₂ 0–100%, accuracy ±2% (70–100%); PR 0–254 bpm, ±2; perfusion index (PI)
    • Anesthetic gas module:AG (Masimo): CO₂ 0–15 vol.%, N₂O 0–100%, sevoflurane 0–10%, desflurane 0–22%, isoflurane/enflurane/halothane 0–8%; MAC; AwRR 0–150 br/min
    • Display:12.1″ color TFT LCD
    • Interface:Ukrainian-language
    • Patient categories:adults, children, neonates
    • ECG:3-lead (I, II, III), 5-lead (+aVR, aVL, aVF, V) or 12-lead (option: I, II, III, aVR, aVL, aVF, V1–V6); HR 15–300 bpm, accuracy ±1%; ST analysis, arrhythmia detection
    • Respiration (RESP):impedance method; 0–120 br/min (adults), 0–150 (children/neonates); apnea alarm
    • NIBP:oscillometric; manual / auto / STAT; SYS 40–270, DIA 10–215, MEAN 20–235 mmHg; accuracy ±5 mmHg
    • Temperature:2 channels (T1/T2); 0–50°C, ±0.1°C
    • Defibrillation protection:yes, signal recovery < 3 s
    • Power supply:100–240 V, 50/60 Hz; built-in battery
    • Operating conditions:0…+40°C, humidity ≤ 85%
    Monitor main unit 1 pc.
    ECG cable (5-lead) 1 pc.
    NIBP cuff and extension tube 1 set
    SpO₂ sensor 1 pc.
    Temperature sensor 1 pc.
    Power and grounding cable 1 set
    Disposable ECG electrodes 5 pcs.
    Configurations iHT6
    Choose a module for your clinical task
    Base EtCO₂ sidestream EtCO₂ mainstream Masimo CO₂ AG gases BIS anesthesia C.O. output
    What it measures 6 parametersCO₂ gas samplingCO₂ in circuitCO₂ Masimo5 gases + MACEEG brain activitycardiac output
    For whom intensive careall patientsintubatedICUanesthesiaanesthesiahemodynamics
    Price 156 900201 800201 800291 800605 800605 800274 800
    INDIVIDUAL SELECTION

    We will find a solution for your facility

    We will help define the required specifications, choose the right equipment and agree on the best terms of cooperation.

    Related products

    Call Telegram Get a quote
    Telegram Viber