EN
UA RU EN

Letres iHT6 Patient Monitor with Capnography (Masimo CO₂)

Price: 291 800,00 ₴SKU: 100083
Availability: In stock
Add modules to configuration*
Total: 291 800,00 ₴
Quantity:

The expert-class patient monitor Letres iHT6 configured with the Masimo CO₂ module for continuous monitoring of EtCO₂ and respiratory rate. The key difference of this configuration is a fast warm-up of under 10 seconds and an AwRR range of 0–150 bpm for all patient categories.

Expert iHT6 platform
Masimo CO₂ capnography
Real-time EtCO₂
Warm-up < 10 s
AwRR 0–150 for all patients
Advanced respiratory monitoring
Further modular expansion
Ukrainian-language interface UA menuMonitor menu available in Ukrainian
  • Description
  • Specifications
  • Configuration
  • Letres iHT6 Patient Monitor with Masimo CO₂

    Letres iHT6 with Masimo CO₂ is a configuration for facilities that need not just EtCO₂ but a Masimo capnography module with clearly defined specifications.

    For Masimo ISA CO₂ the manual specifies a warm-up to full accuracy of less than 10 seconds and a respiratory rate range of 0–150 bpm for all patient categories. Total system response time is under 3 seconds, sample flow is 50 ± 10 mL/min.

    The module works as part of the iHT6, so the CO₂ waveform and respiratory values are displayed together with the patient’s standard and additional parameters. Masimo CO₂ thus becomes part of a comprehensive configuration rather than a separate capnograph.

    How Masimo CO₂ differs from basic capnography

    According to the iHT manual, the Masimo module differs from the basic sidestream module in these specifications:

    Fast warm-up — under 10 seconds to full accuracy; the basic module needs up to 2 minutes.
    One respiratory rate range for everyone — AwRR 0–150 bpm; the basic module covers 7–120 bpm for adults.
    Short automatic zeroing — under 3 seconds; the basic module takes 5–8 seconds.

    CO₂ and respiration monitoring

    Masimo CO₂ provides continuous display of the capnogram, EtCO₂, inspired CO₂ and respiratory rate.

    The module is designed for continuous operation where capnography is an important part of overall monitoring and a fast start matters.

    Letres iHT6 with Masimo CO₂ — Key Features

    Masimo capnography — the Masimo CO₂ module is integrated directly into the iHT6 platform.
    Fast start-up — warm-up to specified accuracy takes less than 10 seconds.
    AwRR 0–150 for all patients — one respiratory rate range for adults, children and neonates.
    Short auto-zeroing — automatic zeroing takes less than 3 seconds.
    Continuous EtCO₂ — the monitor shows end-tidal CO₂ and respiratory data in real time.
    Real-time capnogram — the physician sees not only the value but also the shape of the CO₂ waveform.
    One platform with the iHT6 — capnography data are combined with the monitor’s other parameters.
    Further modular expansion — IBP, C.O., CSM and other available technologies can be added.

    What Your Facility Gets

    Masimo capnography in the iHT6 line — a separate configuration with a Masimo CO₂ module.
    A fast start of monitoring — the module reaches full accuracy in less than 10 seconds.
    One range for different patients — AwRR 0–150 bpm without separate adult limits.
    Fewer interruptions in measurement — automatic zeroing lasts less than 3 seconds.
    Real-time ventilation monitoring — EtCO₂, the capnogram and AwRR complement standard monitoring.
    A single workstation — Masimo CO₂ combines with the iHT6 haemodynamic modules and CSM.
    Room for further development — the facility can add new modules as needed.
    Ukrainian-language interface Menu — the Ukrainian interface makes everyday work easier for staff.

    Who It Is For

    Masimo CO₂ suits departments where capnography is a regular and important monitoring channel: operating rooms, intensive care, resuscitation and other areas of long-term or intensive respiratory monitoring.

    Masimo CO₂ and AG Are Different Configurations

    Masimo CO₂ is capnography: EtCO₂, inspired CO₂, the capnogram and respiratory rate.

    Anaesthetic gas analysis — N₂O, inhalational anaesthetics, MAC — is a separate iHT6 configuration with the AG module. The Masimo CO₂ module does not provide AG functions.

    Letres iHT6 with Masimo CO₂ for Your Facility

    Letres iHT6 with Masimo CO₂ is a capnography configuration for facilities that need a fast start, one respiratory rate range for all patients and CO₂ monitoring integrated into a single modular system.

    Letres Company will help select accessories, confirm the configuration and combine Masimo CO₂ with other iHT6 modules for your department’s tasks.

    • SpO₂ / pulse:SpO₂ 0–100%, accuracy ±2% (70–100%); PR 0–254 bpm, ±2; perfusion index (PI)
    • Capnography module:Masimo ISA CO₂; CO₂ 0–15 vol%, accuracy ±(0.2 vol% + 2%); AwRR 0–150 bpm; warm-up < 10 s; system response time < 3 s; sample flow 50 ± 10 mL/min
    • Display:12.1″ color TFT LCD
    • Interface:Ukrainian-language
    • Patient categories:adults, children, neonates
    • ECG:3-lead (I, II, III), 5-lead (+aVR, aVL, aVF, V) or 12-lead (option: I, II, III, aVR, aVL, aVF, V1–V6); HR 15–300 bpm, accuracy ±1%; ST analysis, arrhythmia detection
    • Respiration (RESP):impedance method; 0–120 breaths/min (adults), 0–150 (children/neonates); apnea alarm
    • NIBP:oscillometric; manual / auto / STAT; SYS 40–270, DIA 10–215, MEAN 20–235 mmHg; accuracy ±5 mmHg
    • Temperature:2 channels (T1/T2); 0–50 °C, ±0.1 °C
    • Defibrillation protection:yes, signal recovery < 3 s
    • Power supply:100–240 V, 50/60 Hz; built-in battery
    • Operating conditions:0…+40 °C, humidity ≤ 85%
    Monitor main unit 1 pc
    ECG cable (5-lead) 1 pc
    NIBP cuff and extension tube 1 set
    SpO₂ sensor 1 pc
    Temperature sensor 1 pc
    Power and grounding cable 1 set
    Disposable ECG electrodes 5 pcs
    Configurations iHT6
    Choose a module for your clinical task
    Base EtCO₂ sidestream EtCO₂ mainstream Masimo CO₂ AG gases BIS anesthesia C.O. output
    What it measures 6 parametersCO₂ gas samplingCO₂ in circuitCO₂ Masimo5 gases + MACEEG brain activitycardiac output
    For whom intensive careall patientsintubatedICUanesthesiaanesthesiahemodynamics
    Price 156 900201 800201 800291 800605 800605 800274 800
    INDIVIDUAL SELECTION

    We will find a solution for your facility

    We will help define the required specifications, choose the right equipment and agree on the best terms of cooperation.

    Related products

    Call Telegram Get a quote
    Telegram Viber