Letres iHT6 Patient Monitor with Cardiac Output (C.O. Module)

Price: 274 800,00 ₴SKU: 100082
Availability: In stock
Add modules to configuration*
Total: 274 800,00 ₴
Quantity:

The expert-class patient monitor Letres iHT6 with C.O. module is designed for advanced haemodynamic monitoring with direct cardiac output measurement by thermodilution. It determines C.O., C.I. and blood temperature, works with a series of thermodilution measurements and combines the results with other monitoring parameters on the single modular iHT6 platform.

iHT6 expert platform
Cardiac output C.O.
Thermodilution method
Advanced hemodynamic monitoring
C.O. and blood temperature
Averaging of several measurements
Further modular expansion
Ukrainian-language interface UA menuMonitor menu available in Ukrainian
  • Description
  • Specifications
  • Configuration
  • Letres iHT6 Patient Monitor with C.O. Module

    Letres iHT6 configured with the C.O. module is designed for clinical situations that call for an in-depth assessment of the patient’s haemodynamics. The cardiac output module complements standard monitoring with direct measurement of C.O., calculation of C.I. and blood temperature monitoring.

    Measurement is performed by thermodilution. The system records the blood temperature response, plots the corresponding curve and calculates cardiac output from it. The physician can take several consecutive measurements, compare the curves and use the averaged result for further assessment.

    At the same time, the iHT6 remains part of a single modular monitoring system. C.O. data can be assessed together with the other parameters available in a given configuration, giving a fuller picture of the patient’s condition without switching between separate systems.

    From standard monitoring to advanced haemodynamics

    Standard parameters cover the main vital signs but do not give a direct quantitative value of cardiac performance.

    The C.O. module adds cardiac output — the volume of blood the heart pumps per unit of time. C.I. complements this assessment by taking the patient’s body surface area into account.

    Combined with other haemodynamic and respiratory parameters, this allows a more comprehensive assessment of the patient, especially when blood pressure, heart rate or saturation values alone are not enough to fully evaluate circulation.

    The modular architecture of the iHT6 lets you extend the configuration for the department’s tasks — including IBP, EtCO₂, AG, BIS/CSM modules and other available technologies.

    How cardiac output is measured

    C.O. is determined by thermodilution. After an indicator of known temperature is injected, the system records the change in blood temperature and builds a thermodilution curve.

    From this curve the monitor calculates cardiac output. Several consecutive measurements can be taken in one session and compared with each other.

    Each measurement is shown as a separate curve, so the physician can check the quality of the results and exclude values that do not fit the series.

    After the valid measurements are selected, the system produces an averaged C.O. result and the corresponding C.I. This way you work with a series of measurements rather than a single random value.

    What the physician sees

    When working with the C.O. module, the monitor displays:

    cardiac output C.O.
    cardiac index C.I.
    blood temperature
    thermodilution curves
    results of individual measurements
    the averaged value for the selected series

    The data can be analysed together with the other parameters available in the iHT6 configuration.

    This lets you assess cardiac output not in isolation, but as part of the patient’s overall haemodynamic picture.

    Letres iHT6 with C.O. Module — Key Features

    Direct cardiac output measurement — The system determines C.O. by thermodilution and provides a quantitative measure of cardiac performance.
    Cardiac index calculation — C.I. evaluates the measured cardiac output relative to the patient’s body surface area.
    Blood temperature monitoring — The module records blood temperature as part of the thermodilution measurement.
    Thermodilution curves — Each measurement comes with a curve, so the quality of the result can be assessed.
    Series of consecutive measurements — Several measurements can be taken in a row and compared with each other.
    Averaging of results — Selected valid measurements are used to calculate the mean C.O.
    Integration with other parameters — Cardiac output data can be assessed together with other monitoring values in one system.
    Further modular expansion — The iHT6 configuration can be extended with additional modules for the needs of a specific department.

    What Your Facility Gets

    Advanced haemodynamic assessment — Cardiac output and cardiac index add direct quantitative measures of heart function to standard monitoring.
    A single monitoring platform — The iHT6 combines basic and advanced parameters in one monitor.
    A configuration built around clinical tasks — Modules can be selected for the needs of intensive care, the operating room or an anaesthesia workstation.
    Room for further expansion — As requirements change, the facility can add new modules without replacing the main platform.
    A comprehensive picture of the patient — C.O. and C.I. can be analysed together with other haemodynamic, respiratory and standard parameters.
    Measurement quality control — Thermodilution curves let you check each result before it is included in the series.
    Work with averaged values — The physician uses the mean of several valid measurements rather than a single reading.
    Ukrainian-language interface Menu — The Ukrainian interface makes system setup and daily work easier for staff.

    Who the Letres iHT6 with C.O. Module Is For

    The Letres iHT6 with C.O. is suited to departments that need an advanced assessment of the patient’s haemodynamic status.

    These include intensive care units, operating rooms, anaesthesia workstations and other clinical areas where cardiac output must be monitored together with other parameters.

    The modular architecture allows both a specialised haemodynamic configuration and a more comprehensive system with additional modules.

    A Configuration for Your Department

    The Letres iHT6 is not limited to a fixed set of parameters. The configuration is built around the clinical tasks and requirements of a specific facility.

    IBP, EtCO₂, AG, BIS/CSM and other available modules can be added to the C.O. system.

    Before ordering, the required parameters, sensors and accessories can be agreed so that the monitor fits the real use case in the department.

    Letres iHT6 with C.O. Module for Your Facility

    The Letres iHT6 with C.O. combines direct cardiac output measurement, C.I. analysis, work with thermodilution curves and further expansion on a single expert platform.

    Letres Company will help select the right configuration, confirm the scope of delivery and prepare technical documentation and a commercial offer for your facility.

    • SpO₂ / pulse:SpO₂ 0–100%, accuracy ±2% (70–100%); PR 0–254 bpm, ±2; perfusion index (PI)
    • Cardiac output module (C.O.):thermodilution, C.O. 0.1–20 L/min, accuracy ±5% or ±0.1 L/min, blood temperature TB 23–43 °C, ±0.1 °C, C.I. and mean over a series of measurements, not for neonates
    • Display:12.1″ color TFT LCD
    • Interface:Ukrainian-language
    • Patient categories:adults, children, neonates
    • ECG:3-lead (I, II, III), 5-lead (+aVR, aVL, aVF, V) or 12-lead (option: I, II, III, aVR, aVL, aVF, V1–V6); HR 15–300 bpm, accuracy ±1%; ST analysis, arrhythmia detection
    • Respiration (RESP):impedance method; 0–120 breaths/min (adults), 0–150 (children/neonates); apnea alarm
    • NIBP:oscillometric; manual / auto / STAT; SYS 40–270, DIA 10–215, MEAN 20–235 mmHg; accuracy ±5 mmHg
    • Temperature:2 channels (T1/T2); 0–50 °C, ±0.1 °C
    • Defibrillation protection:yes, signal recovery < 3 s
    • Power supply:100–240 V, 50/60 Hz; built-in battery
    • Operating conditions:0…+40 °C, humidity ≤ 85%
    Main monitor unit 1 pc
    ECG cable (5-lead) 1 pc
    NIBP cuff and extension tube 1 set
    SpO₂ probe 1 pc
    Temperature probe 1 pc
    Power and grounding cable 1 set
    Disposable ECG electrodes 5 pcs
    Configurations iHT6
    Choose a module for your clinical task
    Base EtCO₂ sidestream EtCO₂ mainstream Masimo CO₂ AG gases BIS anesthesia C.O. output
    What it measures 6 parametersCO₂ gas samplingCO₂ in circuitCO₂ Masimo5 gases + MACEEG brain activitycardiac output
    For whom intensive careall patientsintubatedICUanesthesiaanesthesiahemodynamics
    Price 156 900201 800201 800291 800605 800605 800274 800
    INDIVIDUAL SELECTION

    We will find a solution for your facility

    We will help define the required specifications, choose the right equipment and agree on the best terms of cooperation.

    Related products

    Call Telegram Get a quote
    Telegram Viber